Insert the O-rings on the two inspection covers (1, fig. 102) and mount the covers using 4 M6 x 14 screws
(1, fig. 103).
Set the screws with a torque wrench, as shown in Section 3.
Mount the shaft end cover and affix it to the casing using 3 M8 x 20 screws (1, fig. 104). Set the screws with
a torque wrench, as shown in Section 3.
Screw in the three plungers (1, fig. 101) and set using an open-ended torque wrench as shown in Section 3).