SVS1 Series

22



NOTE:

in Monitor Mode it is possible, as already mentioned, to check that the inspection settings

function properly. It is however important to highlight that the inspection displayed on the VSC does
not correspond to that saved on the sensor until the user saves it in one of the memory slots on the
sensor. For this reason, every time the user makes any modifications to the configuration settings, in
monitor mode, the floppy disk icon in the bottom right hand corner will flash reminding the user to save
the inspection.

Example:

Let's connect the VSC to a SVS1 which is currently monitoring. The device will switch to Monitor Mode
and display the current sensor functions.

We then decide to increase the minimum acceptance threshold of the pattern match tool as
sometimes the inspection does not provide the desired results. We therefore press ESC to return to
Adjust mode and press ARROW UP to increase the threshold. We now return to Monitor mode to
check the results by pressing the STATUS button.

The floppy disk icon will flash in the top right hand corner. If we now disconnect the VSC from the
SVS1, we would lose all the modifications. To save the new settings, press STATUS to enter the
System menu and use the bank set we save the inspection to a sensor memory slot (please see
paragraph 5.7 for further details).