Instruction Manual

SVS1 Series

25


Two other parameters which can be configured can be seen at the bottom of the screen.

Duration

this indicates the length of time (in ms) the output must maintain the last acquired

value; this is mainly used for Part Present, Part Pass and Part Fail modes.

Delay

indicates after how long the output shall display the last acquired result. It delays the

time the output signal is maintained if the delay is longer than the processing time, therefore
from when the image is acquired to when the outputs are enabled.


These two parameters can be set using the LEFT/RIGHT ARROW buttons.

Once the settings have been completed, it is possible to return to the System menu and save the
modifications by pressing the TEACH button. Press ESC if you wish to exit without saving the
modifications. The system will display save request message. To confirm exit and ignore the
modifications, use the ARROWS to reach NO and press SET.

The configuration phase has been concluded when all the output settings have been completed. Now
you must render the modifications permanent and save the inspection to the sensor databank.
Select the DATABANK option from the main menu, and press the SET button.

It is possible to manage the sensor memory slots from the new menu displayed on the screen. SVS1
has a total of 8 databank areas where it is possible to save 8 different inspections which can be
recalled as required.

To save the configured inspection, select the destination databank using the ARROW buttons and
then press SET to confirm. Then move the cursor to SAVE and press SET.