Vsc configurator: advanced functions, Output – IDEC DATAVS1 Series User Manual

Page 32

Advertising
background image

Instruction Manual

SVS1 Series

27

6.

VSC CONFIGURATOR: ADVANCED FUNCTIONS


The previous chapter described the procedure used to create a new inspection for SVS1. Besides the
functions illustrated above, there are other user settings on the VSC configurator which can be
reached from the System menu.

These functions are listed and individually described below.

6.1.

Output

From the Output Settings menu it is possible to configure the 3 digital outputs on the sensor. A
different behaviour can be associated to each output.

Option

Behaviour

Part pass The output is enabled when the control gives a positive result. If a failure occurs it

remains low.

Part fail

The output is enabled if a failure occurs. If the control gives a positive result, it
remains disabled.

Busy-
Ready

The output takes on value 1 (Busy) for the entire time the sensor takes to acquire and
process the image. The output takes on value 0 (Ready) when the sensor is ready to
acquire a new image. If the image is acquired under the control of an external signal
(hardware trigger), the output will take on value 1 on receiving the signal.

Error

This indicates an error on the sensor.

Toggle

The output will take on alternately the logic values 1 and 0 each time it acquires and
processes an image. In this configuration there is no relation between the value taken
on by the output and the result of the processed image.

Disable

The output is disabled