Switch status symbols

The symbols can appear on the Status Bar:

–Green Circle

–Yellow Triangle

–Red Diamond with Yellow Background

–Grey Square

Table 2

describes the Status Bar symbols.

Table 2

Status Bar symbols

Status Bar

Switch status table text

Description

Green Circle

Fully Operational

All components and installed ports are operational; no
failures.

Yellow Triangle

Redundant Failure

A redundant component has failed, such as a power
supply, and the backup component has taken over
operation.

Minor Failure

A failure occurred which has decreased the switch
operational ability. Normal switching operations are not
affected.

Red Diamond
with Yellow
Background

NOT OPERATIONAL

A critical failure prevents the switch from performing
fundamental switching operations.

All fans failed.

An installed port failed.

Both power supplies failed.

Gray Square

Never Connected

Link Timeout

Protocol Mismatch

Duplicate Session

Unknown Network Address

Incorrect Product Type

Switch status is unknown. This occurs if the Ethernet network
connection between the HAFM appliance and the switch
cannot be established or if the CTP fails. See the No Link
Status bullet description in ”

Switch status table

” on page 46

for details on the status table text.