Table 29 zoning problems and resolutions, 29 zoning problems and resolutions – HP StorageWorks 2.140 Director Switch User Manual

Page 209

Advertising
background image

HA-Fabric Manager user guide 213

Table 29

Zoning problems and resolutions

Problem

Cause/resolution

Receiving zoning errors.

Verify that you did not configure zoning on a

non-principal switch.

The application is not performing

zoning discovery very often.

Zoning discovery is performed once at startup, and

then once every two hours during routine discovery.

If the Zoning dialog box is open, zoning discovery is

performed during every polling cycle. It continues to

discover at the increased speed for 30 minutes

before it returns to the default value.

When activating a large zone set

on a two-switch fabric on UNIX

platforms, an error message is

displayed stating

Failed to

perform the requested

zoning action: Failed to

zone due to exception

COM.hp.hafmecc.HafmUnava

ilableException

.

Although the error message states that the requested

zoning action failed, the zone set correctly activated.

Wait for the next zoning polling to occur.

Zoning activation message is

displayed for a long time, but

zone set is not activated.

Telnet zoning can take a long time. To improve

speed, open the Discover Setup dialog box and add

the HAFM IP address for HP switches to the Selected

Individual Addresses

list.

When opening the Zoning dialog

box from a particular switch or

fabric, the message

Cannot

zone the selected device

or fabric

is displayed.

The application can have been unable to log in to

the fabric due to another active session. Verify that

there is not another active session.
The application cannot support zoning on any of the

discovered products.

Advertising