1 attach the mvp 25-pin d-sub connector to the mvp – Electronics International MVP-50T User Manual

Page 36

Advertising
background image

When routing the MVP wire harness refer to the "MVP-50 25-pin D-Sub Connector Wiring Diagram" found at
the back of this manual. Insure no wires obstruct the freedom of travel of any controls.

4.1 Attach the MVP 25-pin D-sub Connector to the MVP:

Secure the connector using the supplied mounting screws.

4.2 Connect the EDC RS422 Wires to the MVP RS422 Wires:

Route the EDC RS422 wires to the back of the MVP Display, cut the wires to length and splice them to the
appropriate MVP RS422 wires.

4.3 Connect the MVP Harness to the Master Warning and Caution Lights:

If the Warning and Caution Lights are installed, route the MVP Master Warning Out wire (White/Yellow, Pin
16) to the Master Warning (Red) Light (AL-1R) White/Yellow wire, cut the wires to length, install the appropri-
ate connectors (see the “Working with Connectors” section of this manual for more information) and connect
to the AL-1R.

Route the MVP Master Caution Out wire (White/Yellow, Pin 17) to the Master Caution (Yellow) Light (AL-1Y)
White/Yellow wire, cut the wires to length, install the appropriate connectors (see the “Working with Connec-
tors” section of this manual for more information) and connect to the AL-1Y.

33

Control Panel

White/Brown

White/Red

White/Orange

(OFF)

(ACK)

(+5V)

MVP

Voice Control

Inputs

20

21
22

Pin 16

To MVP/EDC

5-amp Circuit

Breaker

Wht/Yel

Red

Red

Wht/Yel

Red

Y e l

Pin 17

4.4 Connect the MVP Harness to the Voice Alarm Control Panel (AV-17CP):

If the voice alarms provided by the MVP are to be used, route the three MVP Voice Control wires to the AV-
17CP, cut the wires to length, install the appropriate connectors (see the “Working with Connectors” section of
this manual for more information) and connect to the AV-17CP.