Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual
Page 115
Safety engineering
Appendix
Module internal codes
l
115
EDS94AYAE EN 7.0
Index:
Data type:
Name:
Parameter:
C15016
Parameter set version
UNSIGNED_8
9559
d
= 2557
h
Display of the parameter set version in the safety module.
Selection list
(read only)
Information
0 No current parameter set
(From SM301 V1.1)
1 Parameter set V1.0
2 Parameter set V1.1
3 Parameter set V1.2
(From SM301 V1.2)
4 Parameter set V1.3
(From SM301 V1.3)
5 Parameter set V1.4
(From SM301 V1.4)
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15017
Stored module ID
UNSIGNED_16
9558
d
= 2556
h
Module ID stored in the safety module
Display area
(min. value | unit | max. value)
Information
0
65535
(As of SM301 V1.2)
Default setting (invalid ID): 0
Stored ID defective: 65535
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15030
SD-In sensor type
UNSIGNED_8
9545
d
= 2549
h
Configuration of the sensor types which are connected to the safe inputs.
Selection list
(Lenze setting bold)
Information
0 Input deactivated
1 Passive sensor
2 Active sensor
Subcodes
Information
C15030/1
SD-In1 sensor type
C15030/2
SD-In2 sensor type
C15030/3
SD-In3 sensor type
C15030/4
SD-In4 sensor type
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15031
SD-In sensor function
UNSIGNED_8
9544
d
= 2548
h
Function configuration of the safe inputs.
l
The "operation mode selector" and "enable switch" functions may only be assigned to one of the four safe
inputs.
Selection list
(Lenze setting printed in bold)
Information
0 Free assignment
Safety function set in C15032
1 Emergency stop
Safe stop emergency function (SSE)
2 Operation mode selector
Safe operation mode selector (OMS)
3 Enable switch
Safe enable switch (ES)
Subcodes
Information
C15031/1
SD-In1 sensor function
C15031/2
SD-In2 sensor function
C15031/3
SD-In3 sensor function
C15031/4
SD-In4 sensor function
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer