Safety engineering

Appendix

Module internal codes

1

l

115

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15016

Parameter set version

UNSIGNED_8

9559

d

= 2557

h

Display of the parameter set version in the safety module.

Selection list

(read only)

Information

0 No current parameter set

(From SM301 V1.1)

1 Parameter set V1.0

2 Parameter set V1.1

3 Parameter set V1.2

(From SM301 V1.2)

4 Parameter set V1.3

(From SM301 V1.3)

5 Parameter set V1.4

(From SM301 V1.4)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15017

Stored module ID

UNSIGNED_16

9558

d

= 2556

h

Module ID stored in the safety module

Display area

(min. value | unit | max. value)

Information

0

65535

(As of SM301 V1.2)

Default setting (invalid ID): 0
Stored ID defective: 65535

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15030

SD-In sensor type

UNSIGNED_8

9545

d

= 2549

h

Configuration of the sensor types which are connected to the safe inputs.

Selection list

(Lenze setting bold)

Information

0 Input deactivated

1 Passive sensor

2 Active sensor

Subcodes

Information

C15030/1

SD-In1 sensor type

C15030/2

SD-In2 sensor type

C15030/3

SD-In3 sensor type

C15030/4

SD-In4 sensor type

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15031

SD-In sensor function

UNSIGNED_8

9544

d

= 2548

h

Function configuration of the safe inputs.

l

The "operation mode selector" and "enable switch" functions may only be assigned to one of the four safe
inputs.

Selection list

(Lenze setting printed in bold)

Information

0 Free assignment

Safety function set in C15032

1 Emergency stop

Safe stop emergency function (SSE)

2 Operation mode selector

Safe operation mode selector (OMS)

3 Enable switch

Safe enable switch (ES)

Subcodes

Information

C15031/1

SD-In1 sensor function

C15031/2

SD-In2 sensor function

C15031/3

SD-In3 sensor function

C15031/4

SD-In4 sensor function

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer