Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual
Page 131
Safety engineering
Appendix
Module internal codes
l
131
EDS94AYAE EN 7.0
Index:
Data type:
Name:
Parameter:
8682
d
= 21EA
h
BITFIELD_64
Log state
C15893
Bit 4 SS1 via SD−In
SS1 was triggered via a safe input.
Bit 5 SS1 via S−bus
SS1 was triggered via the safety bus.
Bit 6 SS1 through error
SS1 was triggered through an error.
Bit 7 Reserved
−
Bit 8 SS2 via SD−In
SS2 was triggered via a safe input.
Bit 9 SS2 via S−bus
SS2 was triggered via the safety bus.
Bit 10 SS2 through error
SS2 was triggered through an error.
Bit 11 Reserved
−
Bit 12 SLS1 via SD−In
SLS1 was triggered via a safe input.
Bit 13 SLS1 via S−bus
SLS1 was triggered via the safety bus.
Bit 14 SLS1 via OMS
SLS1 was triggered via the operating mode changeover.
Bit 15 Reserved
−
Bit 16 SLS2 via SD−In
SLS2 was triggered via a safe input.
Bit 17 SLS2 via S−bus
SLS2 was triggered via the safety bus.
Bit 18 SLS2 via OMS
SLS2 was triggered via the operating mode changeover.
Bit 19 Reserved
−
Bit 20 SLS3 via SD−In
SLS3 was triggered via a safe input.
Bit 21 SLS3 via S−bus
SLS3 was triggered via the safety bus.
Bit 22 SLS3 via OMS
SLS3 was triggered via the operating mode changeover.
Bit 23 Reserved
−
Bit 24 SLS4 via SD−In
SLS4 was triggered via a safe input.
Bit 25 SLS4 via S−bus
SLS4 was triggered via the safety bus.
Bit 26 SLS4 via OMS
SLS5 was triggered via the operating mode changeover.
Bit 27 Reserved
−
Bit 28 SDIpos via SD−In
SDIpos was triggered via a safe input.
Bit 29 SDIpos via S−bus
SDIpos was triggered via the safety bus.
Bit 30 SDIpos via SLS
SDIpos was triggered in combination with SLS.
Bit 31 SDIpos in normal operation
SDIpos was triggered in normal operation.
Bit 32 SDIneg via SD−In
SDIneg was triggered via a safe input.
Bit 33 SDIneg via S−bus
SDIneg was triggered via the safety bus.
Bit 34 SDIneg via SLS
SDIneg was triggered in combination with SLS.
Bit 35 SDIneg in normal operation
SDIneg was triggered in normal operation.
Bit 36 SLI is active
SLI was triggered in special operation.
Bit 37 Reserved
−
Bit 38 Reserved
−
Bit 39 Reserved
−
Bit 40 Special operation via SD−In
Special operation was triggered vi a safe input.
Bit 41 Special operation via S−bus
Special operation was triggered via the safety bus.
Bit 42 Reserved
−
Bit 43 Reserved
−
Bit 44 ES via SD−In
ES was triggered via a safe input.
Bit 45 ES via S−bus
ES was triggered via the safety bus.
Bit 46 Reserved
−
Bit 47 Reserved
−