Safety engineering

Device modules
Safe speed measurement and position detection

1

l

44

EDS94AYAE EN 7.0

Parameter setting of standard device 9400

W

Parameter setting of SM301

Motor mounting

direction

Position encoder mounting

direction

Motor mounting

direction

Position encoder mounting

direction

C02527/0

C02529/0

C15409/0

C15502/0

CW

CW

W

CW

"Like motor encoder"

CW

CCW

W

CW

"Inverted ..."

CCW

CW

W

CCW

"Inverted ..."

CCW

CCW

W

CCW

"Like motor encoder"

Tab. 1−4

Overview of dependency of the parameterisation from the mounting direction

(

Stop!

Malfunctions due to slip, shaft fracture etc.
Slip, shaft fracture etc. between motor and encoder system disturb the safe
speed measurement.
Possible consequences:

ƒ

The speed−dependent and/or direction−of−rotation dependent functions are
executed incorrectly.

Protective measures:

ƒ

Prevent malfunctions by constructive measures.

ƒ

Use the motors and encoder systems with guaranteed features. Your Lenze
contact partner helps you to find suitable systems.

ƒ

In the event of service, this must also be observed for the motor or the
encoder system.