Safety engineering

Appendix
Module internal codes

1

l

124

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15308

SS2 mode

UNSIGNED_8

9267

d

= 2433

h

Selection whether SS2 is to be executed already after reaching n=0 SOS or only after reaching the parameterised
stopping time.

Selection list

(Lenze setting bold)

Information

0 SOS after stopping time

(As of SM301 V1.3)

1 SOS at n = 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15310

Tolerance window (n=0)

INTEGER_16

9265

d

= 2431

h

Safely monitored tolerance window for zero speed

Setting range

(min. value | unit | max. value)

Information

0

rpm

16000 Lenze: 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15311

SOS: Tolerance window (Delta p=0)

UNSIGNED_32

9264

d

= 2430

h

Safely monitored tolerance window for zero position change

Display area

(min. value | unit | max. value)

Information

0

Incr.

327680 Lenze: 0

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15312

SOS: Maximum change in position

UNSIGNED_32

9263

d

= 242F

h

Amount of the maximum change in position while SOS was active

Display area

(min. value | unit | max. value)

Information

0

Incr.

2147483647

(From SM301 V1.3)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15315

SS1, SS2: ramp monitoring

UNSIGNED_8

9260

d

= 242C

h

Selection whether the brake ramp is to be monitored when SS1 and SS2 are executed.

Selection list

(Lenze setting bold)

Information

0 No ramp monitoring

(From SM301 V1.4)

1 Ramp monitoring is activated

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15316

SS1, SS2: S−ramp time

UNSIGNED_8

9259

d

= 242B

h

S−ramp time of deceleration ramp for SS1 and SS2 if a linear ramp is not used.

Setting range

(min. value | unit | max. value)

Information

0

%

100 0

(From SM301 V1.4)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15317

SS1, SS2: Start offset ramp

UNSIGNED_8

9258

d

= 242A

h

Speed offset at the start of the ramp monitoring.

Display area

(min. value | unit | max. value)

Information

0

%

30 0

(From SM301 V1.4)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15320

SMS: Max. speed Nmax

INTEGER_16

9255

d

= 2427

h

Selection of the maximum speed and activation of the SMS function

Setting range

(min. value | unit | max. value)

Information

0

rpm

16000 Lenze: 1, deactivate: 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer