CDM-700 High Speed Satellite Modem

Revision 5

Front Panel Operation

MN/CDM700.IOM

6–8

6.3.1.1 (CONFIG:)

Remote

Remote Control:
Local Serial Ethernet

Select Local, Serial or Ethernet by using the ◄ ► arrow keys, then press

ENTER

.

Selection

Action

Local

Remote control is disabled. Remote monitoring is still possible.

Serial

RS232, RS485-2W, and RS485-4W menus are accessed.

Ethernet

Additional submenus will be displayed.

Remote Control:

Æ Local

IMPORTANT

When Local is selected, remote control is disabled and local control enabled
once
ENTER is pressed; the CONFIG: menu returns. When Remote is selected,
menu operations associated with local control are disabled, and the following
message appears when menu or command access associated with Local
control is attempted:

THIS UNIT IS CURRENTLY
IN REMOTE MODE!!

Remote Control:

Æ Serial

Serial Config: Interface Baudrate
(
E)

Select Interface or Baudrate using the ◄ ► arrow keys, then press

ENTER

.


If Serial Config: Æ Interface is selected:

M&C Bus Interface: RS232
RS485-2W RS485-4W (
E)


Select RS232 or RS485-2W (2-wire) or RS485-4W (4-wire) using the ◄ ► arrow keys, then
press

ENTER

.


Note: At this point, a prompt requests entry of the bus address.