Checking and changing q parameters 9.7 – HEIDENHAIN TNC 640 (34059x-05) ISO programming User Manual
Page 303
Checking and changing Q parameters
9.7
9
TNC 640 | User's ManualDIN/ISO Programming | 1/2015
303
You can have the Q parameters be shown in the additional status
display in all operating modes (except for the
Programming
operating mode).
If you are in a program run, interrupt it if required (for example,
by pressing the machine STOP button and the soft key). If you
are in a test run, interrupt it.
Call the soft-key row for screen layout
Select the screen layout with additional status
display: In the right half of the screen, the TNC
shows the
Overview status form
Press the
STATUS OF Q PARAM. soft key
Press the
Q PARAMETER LIST soft key: The TNC
opens a pop-up window
For each parameter type (Q, QL, QR, QS), define
the parameter numbers you wish to control.
Separate single Q parameters with a comma, and
connect sequential Q parameters with a hyphen,
e.g. 1,3,200-208. The input range per parameter
type is 132 characters.
The display in the
QPARA tab always contains eight
decimal places. The result of Q1 = COS89.999 is
shown by the control as 0.00001745 for example.
Very large or very small values are displayed by
the control in exponential notation. The result of
Q1 = COS 89.999 * 0.001 is shown by the control as
+1.74532925e-08, whereby e-08 corresponds to the
factor of 10
-8
.