String parameters 9.10 – HEIDENHAIN TNC 640 (34059x-05) ISO programming User Manual
Page 337
String parameters
9.10
9
TNC 640 | User's ManualDIN/ISO Programming | 1/2015
337
Reading a string of a machine parameter
In order to store the content of a machine parameter as a string in
a QS parameter:
press the
Q key.
Select the
STRING FORMULA function
Enter the number of the string parameter in
which the TNC is to save the machine parameter.
Confirm with the
ENT key
Select the CFGREAD function
Enter the numbers of the string parameters for
the key, entity and attribute, then confirm with the
ENT key
Enter the number for the index, or skip the dialog
with NO ENT, whichever applies
Close the parenthetical expression with the
ENT
key and confirm your entry with the
END key
Example: Read as a string the axis designation of the fourth
axis
Parameter settings in the configuration editor
DisplaySettings
CfgDisplayData
axisDisplayOrder
[0] to [5]
14 DECLARE STRINGQS11 = ""
Assign string parameter for key
15 DECLARE STRINGQS12 = "CFGDISPLAYDATA"
Assign string parameter for entity
16 DECLARE STRINGQS13 = "AXISDISPLAYORDER"
Assign string parameter for parameter name
17 QS1 =
CFGREAD( KEY_QS11 TAG_QS12 ATR_QS13 IDX3 )
Read out machine parameter