Setting handshaking (flowcontrol), File system for file operations (filesystem), Block check character (bccavoidctrlchar) – HEIDENHAIN TNC 640 (34059x-05) ISO programming User Manual
Page 590: Condition of rts line (rtslow), Mod functions 18.10 setting up data interfaces
MOD functions
18.10 Setting up data interfaces
18
590
TNC 640 | User's ManualDIN/ISO Programming | 1/2015
Setting handshaking (flowControl)
By handshaking, two devices control data transfer between them.
A distinction is made between software handshaking and hardware
handshaking.
No data flow checking (NONE): Handshaking is not active
Hardware handshaking (RTS_CTS): Transmission stop is active
through RTS
Software handshaking (XON_XOFF): Transmission stop is active
through DC3 (XOFF)
File system for file operations (fileSystem)
In
fileSystem you define the file system for the serial interface.
This machine parameter is not required if you don't need a special
file system.
EXT: Minimum file system for printers or non-HEIDENHAIN
transmission software. Corresponds to the EXT1 and EXT2
modes of earlier TNC controls.
FE1: Communication with the TNCserver PC software or an
external floppy disk unit.
Block Check Character (bccAvoidCtrlChar)
With Block Check Character (optional) no control character, you
determine whether the checksum can correspond to a control
character.
TRUE: The checksum does not correspond to a control character
FALSE: The checksum can correspond to a control character
Condition of RTS line (rtsLow)
With Condition of RTS line (optional) you determine whether the
"low" level is active in idle state.
TRUE: Level is "low" in idle state
FALSE: Level is not "low" in idle state