Io-read – B&B Electronics WLNN-AN(ER,SE,SP.EK)-DP551 - Manual User Manual

Page 164

Advertising
background image

164

Airborne Enterprise CLI Reference Manual

io-read

Command

io-read

Arguments

f<port number> | g<port number>

Security

Level

2 (data)

Device Type All

Default

N/A

Description

Reads the value of the indicated GPIO port and bit. This command is applied dynamically and does not

require a restart.

The command requires a single parameter that identifies the GPIO port and bit to be read, for

example:

io-read f1

:

Reads the value of the f port first bit.

io-read g7

:

Reads the value of the g port seventh bit.

The returned value will be a zero (0) or one (1) based upon the voltage applied to the input. Please

refer to the Airborne DP500 Family data book for the GPIO electrical specification.

Port assignment and exceptions:

f0

Read (POST output)

g0

Read or Write

f1

Read or Write

g1

Read or Write

f2

Read (RF_LINK output)

g2

Read or Write

f3

Read (WLN_CFG output)

g3

N/A

f4

Read or Write

g4

N/A

f5

Read or Write

g5

N/A

f6

Read (LED_CON output)

g6

Read or Write

f7

Read or Write

g7

Read or Write

When the LED signal has not been disabled those bits indicated as LED Outputs can only be read.
Issuing an io-read for any of these ports will return the current status of the LED output (See WLNN
DP500 Family Databook for details). To disable the LED‟s use one of the following commands post-
led

, rf-link-led, wln-cfg-led and conn-led.

Advertising