Airborne Enterprise CLI Reference Manual

pw

Command

pw

Arguments

[ASCII Text string]

Security

Level

Write only: 3 (config)

Device Type All

Default

cfg

Description

Configures the Level 2 password (“data”).

Password must be no longer than 31 ASCII characters and must not include spaces.

**Note: „user‟ must be configured before „pw‟, if a change to the user name is planned!

pw-cfg

Command

pw-cfg

Arguments

[ASCII Text string]

Security
Level

Write only: 3 (config)

Device Type All

Default

cfg

Description

Configures the Level 3 password (“config”).

Password must be no longer than 31 ASCII characters and must not include spaces.

**Note: „user-cfg‟ must be configured before „pw-cfg‟, if a change to the user name is planned!

pw-leap

Command

pw-leap

Arguments

[ASCII Text string]

Security

Level

Write only: 3 (config)

Device Type All

Default

<none>

Description

Configures the WPA-LEAP password.

The LEAP password must match the LEAP password assigned to the LEAP user on the LEAP server.

The LEAP password is 1 to 32 characters in length and cannot contain spaces.