3.4 Fieldbus

Type

Address Map

106

(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)

Signal Type

Bit

Symbol

Description

Details

b15

RUN

This signal turns ON when Gateway is in normal

operation.

b14

LERC

This signal turns ON if the ERR-T or ERR-C

occurred during an operation is retained and turns

OFF if cancel signal RTE is turn ON.

It is effective when ERR-T or ERR-C occurrence

is set to latch in Gateway Parameter Setting Tool.

b13

ERRT

This signal turns ON when a communication error

is detected between the Gateway and each axis.

b12

MOD

This signal turns ON if the operation mode switch

on the front of the unit is selected to be on MANU

side, and turns OFF if on AUTO side.

b11

ALMH

This signal turns ON when an error caused by the

Gateway that requires a reboot is occurred.

(A wrong setting in the parameters can be

considered. Check the parameters settings.)

b10

ALML

This signal turns ON when a light error caused by

the Gateway is occurred.

(It is considered that there shall be a loss of the

calendar data. Check the parameters settings.)

b9

Cannot be used.

b8

SEMG

This signal turns ON when EMGIN input of the

system I/O connector is OFF (emergency stop).

When this bit is turned ON, all the connected axes

get in the emergency stop.

b7
b6
b5
b4
b3
b2
b1

Control

signal 0

b0

ALMC1 to 128

It is an output of an alarm code caused by the

Gateway.

[Refer to Gateway alarm codes in Chapter 6.

Troubleshooting for details.]

b15

MNT7

b14

MNT6

b13

MNT5

b12

MNT4

b11

MNT3

b10

MNT2

b9

MNT1

b8

MNT0

The bit of an axis number that a light error alarm is

generated turns ON.

Axis No.0 = MNT0 to Axis No.7 = MNT7

b7

LNK7

b6

LNK6

b5

LNK5

b4

LNK4

b3

LNK3

b2

LNK2

b1

LNK1

P

LC

In

pu

t

Control

signal 1

b0

LNK0

The bit of the axis number identified as effective

by the Gateway turns ON.

Axis No.0 = LNK0 to Axis No.7 = LNK7