IAI America MSEP User Manual

Page 129

Advertising
background image

3.4 Fieldbus

Type
Address Map

121

(3) I/O signal assignment

(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)

Signal Type

Bit

Symbol

Description

Details

Specified

Position No.

16 bits

Data

PC1 to

PC128

16-bit integer

Available range for Setting: 0 to 255

To operate, it is necessary to have the position data

that the operation conditions are already set in

advance with a teaching tool such as the PC

software.

In this register, indicate the position number the

data is input with a binary number.

Indicating a value out of the range or operating with

a position number with no setting conducted will

generate the alarm code 0A2 “Position Data Error”.

3.8.1 (23)

b15

BKRL

Brake release

ON: Brake release, OFF: Brake activated

3.8.1 [15]

b14
b13

b12

b11

b10

b9

Cannot be used.

b8

JOG+

+Jog

ON: Movement against home position, OFF: Stop

b7

JOG-

-Jog

ON: Movement toward home position, OFF: Stop

3.8.1 [12]

b6

Cannot be used.

b5

JISL

Jog/inching switching

ON: Inching, OFF: Jog

3.8.1 [14]

b4

SON

Servo ON command

ON: Servo ON, OFF: Servo OFF

3.8.1 [5]

b3

RES

Reset

A reset is performed when this signal turns ON.

3.8.1 [4]

b2

STP

Pause

ON: Pause, OFF: Pause release

3.8.1 [10]

b1

HOME

Home return

Home-return command with this signal ON,

command carried on till complete even if the signal

is turned OFF on the way

3.8.1 [6]

P

LC

O

ut

pu

t

Control

Signal

b0

CSTR

Positioning start

Movement command executed with this signal ON,

command carried on till complete even if the signal

is turned OFF on the way

3.8.1 [7]

Advertising