2 encoders with one reference mark – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 131

Advertising
background image


3/97

TNC 406/TNC 306

2 Reference marks

4-31

2.1.2 Encoders with one reference mark

Machine parameter MP1350.x=1

Reference marks

Closed
Open

Trip dog
"Reference end position"

Traverse direction MP1320

For linear measurement using a rotary encoder a reference pulse is produced on each revolution of
the encoder. It must be ensured that, after switching on the machine, always the same reference
pulse is evaluated. This can also be achieved by using the trip dog "Reference end-position."

Reference pulse

Closed

Open

Trip dog
"Reference end position"

Traverse direction MP1320

Measuring length

Desired reference pulse

Advertising