Error codes of heidenhain peripheral devices, 2 error codes of heidenhain peripheral devices – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 454
![background image](/files/815307/content/doc454.png)
3/97
TNC 406/TNC 306
6 Error messages
8-41
6.2 Error codes of HEIDENHAIN peripheral devices
These error messages refer to the FE 401 floppy disk unit and to magnetic tape unit ME 101/
ME 102. With the FE 401 floppy disk unit connected, one of the following error codes could be
output by the TNC:
Error code
Meaning
ERR: 001
Wrong instruction code
ERR: 002
Illegal program name
ERR: 003
Defective data transmission
ERR: 004
Program incomplete
ERR: 010
Program not on floppy disk
ERR: 011
Program protected against erasure
ERR: 012
Program storage in progress
ERR: 013
Program directory full
ERR: 014
Floppy disk full
ERR: 100
Floppy disk not formatted
ERR: 101
Sector number too large
ERR: 102
Drive not ready
ERR: 103
Floppy disk write-protected
ERR: 104
Data on floppy disk defective
ERR: 105
Sectors not found
ERR: 106
Check sum defective
ERR: 107
Disk controller faulty
ERR: 108
DMA faulty
If a magnetic tape unit is connected, the following error codes could be sent to the TNC and an
appropriate error message outputted:
Error code
Error message
<ESC><1><0>
TRANSFERRED DATA INCORRECT
<ESC><1><1>
DATA CARRIER MISSING
<ESC><1><2>
DATA CARRIER WRITE-PROTECTED
<ESC><1><3>
WRONG OPERATING MODE
<ESC><1><4>
WRONG PROGRAM DATA
<ESC><1><5>
DATA CARRIER EMPTY
<ESC><1><6>
PROGRAM INCOMPLETE
<ESC><1><7>
ME: END OF TAPE
A detailed description of these peripherals can be found in the appropriate operating manual.