Eroding, 4 eroding – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 262
![background image](/files/815307/content/doc262.png)
5-14
TNC 416/TNC 406/TNC 306
List of machine parameters
3/2000
Machine
parameter
Function and input
Change
via
Reaction
Page
MP1710.0–4 Position monitoring for operation with lag
(erasable)
Entry range: 0 to 100,000 [mm]
Removed in TNC 406 as of software 280 620-07.
The control now multiplies the value of the normal
servo lag by 1.5 and uses the product as limit for
servo-lag monitoring (erasable error message). A
value of 1.8 * servo lag should therefore be used
for MP1720.x.
4–46
MP1720.0–4 Position monitoring for operation with lag
(Emergency Stop, error A)
Entry range: 0 to 100,000 [mm]
4–46
MP1810.0–4 Kv factor for positioning
Entry range: 0.1 to 10,000
4–42
3.4 Eroding
Machine
parameter
Function and input
Change
via
Reaction
Page
MP2010
MP2010.0
MP2010.1
Characteristic gradient
Entry range: 0.001 to 60 . 000
Input characteristic range 2.5 to 5 V
Input characteristic range 0 to 2.5 V
4–56
MP2020
MP2020.0
MP2020.1
Multiplication factor
Entry range: 1.000 to 10 . 000
Input characteristic range 2.5 to 5 V
Input characteristic range 0 to 2.5 V
4–56
MP2030
MP2030.0
MP2030.1
Characteristic kink
Entry range: 0 to 100 [%]
Input characteristic range 2.5 to 5 V
Input characteristic range 0 to 2.5 V
4–57
MP2040
Factor for following electrode
Entry range: 0.1 to 60,000
123
4–64
MP2050
Move back reapproach position after short circuit
or CYCL STOP
Entry range: 0 to 2 [mm]
123
4–60
MP2051
Move back reapproach position after flushing
Entry range: 0 to 2 [mm]
123
4–61