A separate 37-pin female connector is mounted on the logic unit for the connection to the
manufacturer's proprietary machine control panel. This connector includes the 0 V and +24 V of the
PLC power supply. The PLC inputs I128 to I151 may be connected only with the power supply from
pins 36 and 37, since this power supply is internally secured as required.
LE416/LE 406 connector X46
LE 306 connector X27
Connecting cable Id. Nr. 263 954 ..
D-sub terminal
(female) 37-pin
Assignment
D-sub connector
(male) 37-pin
1
I128
1
Gray/Red
2
I129
2
Brown/Black
3
I130
3
White/Black
4
I131
4
Green/Black
5
I132
5
Brown/Red
6
I133
6
White/Red
7
I134
7
White/Green
8
I135
8
Red/Blue
9
I136
9
Yellow/Red
10
I137
10
Gray/Pink
11
I138
11
Black
12
I139
12
Pink/Brown
13
I140
13
Yellow/Blue
14
I141
14
Green/Blue
15
I142
15
Yellow
16
I143
16
Red
17
I144
17
Gray
18
I145
18
Blue
19
I146
19
Pink
20
I147
20
White/Gray
21
I148
21
Yellow/Gray
22
I149
22
Green/Red
23
I150
23
White/Pink
24
I151
24
Gray/Green
25
I152
25
Yellow/Brown
26
O0
26
Gray/Brown
27
O1
27
Yellow/Black
28
O2
28
White/Yellow
29
O3
29
Gray/Blue
30
O4
30
Pink/Blue
31
O5
31
Pink/Red
32
O6
32
Brown/Blue
33
O7
33
Pink/Green
34
0 V (PLC)
34
Brown
35
0 V (PLC)
35
Yellow/Pink
36
+24 V (PLC)
36
Violet
37
+24 V (PLC)
37
White
Housing
External shield
Housing
External shield