12 machine control panel, 12 machine c ontrol panel – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 73

Advertising
background image


3–58

TNC 416/TNC 406/TNC 306

Machine control panel

3/99

12 Machine c ontrol panel

A separate 37-pin female connector is mounted on the logic unit for the connection to the
manufacturer's proprietary machine control panel. This connector includes the 0 V and +24 V of the
PLC power supply. The PLC inputs I128 to I151 may be connected only with the power supply from
pins 36 and 37, since this power supply is internally secured as required.

LE416/LE 406 connector X46

LE 306 connector X27

Connecting cable Id. Nr. 263 954 ..

D-sub terminal
(female) 37-pin

Assignment

D-sub connector
(male) 37-pin

1

I128

1

Gray/Red

2

I129

2

Brown/Black

3

I130

3

White/Black

4

I131

4

Green/Black

5

I132

5

Brown/Red

6

I133

6

White/Red

7

I134

7

White/Green

8

I135

8

Red/Blue

9

I136

9

Yellow/Red

10

I137

10

Gray/Pink

11

I138

11

Black

12

I139

12

Pink/Brown

13

I140

13

Yellow/Blue

14

I141

14

Green/Blue

15

I142

15

Yellow

16

I143

16

Red

17

I144

17

Gray

18

I145

18

Blue

19

I146

19

Pink

20

I147

20

White/Gray

21

I148

21

Yellow/Gray

22

I149

22

Green/Red

23

I150

23

White/Pink

24

I151

24

Gray/Green

25

I152

25

Yellow/Brown

26

O0

26

Gray/Brown

27

O1

27

Yellow/Black

28

O2

28

White/Yellow

29

O3

29

Gray/Blue

30

O4

30

Pink/Blue

31

O5

31

Pink/Red

32

O6

32

Brown/Blue

33

O7

33

Pink/Green

34

0 V (PLC)

34

Brown

35

0 V (PLC)

35

Yellow/Pink

36

+24 V (PLC)

36

Violet

37

+24 V (PLC)

37

White

Housing

External shield

Housing

External shield

Advertising