3 overview of connections – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 28
3/99
TNC 416/TNC 406/TNC 306
Overview of connections
3–13
3 Overview of connections
LE 416
X1
Measuring system 1 (1Vss/11µA)
X2
Measuring system 2 (1Vss/11µA)
X3
Measuring system 3 (1Vss/11µA)
X4
Measuring system 4 (1Vss/11µA)
X6
Measuring system 5 (1Vss/11µA)
X8
Nominal value outputs 1,2,3,4,5,
gap signal input
X12
Triggering touch probe for workpiece
measurement
X13
Triggering touch probe for tool
measurement
X21
RS-232-C/V24 data interface
X22
RS-422/V11 data interface
X23
Handwheel interface
X41
PLC output
X42
PLC input
X43
BC 120 VDU (alternative to BF 120)
X44
PLC power supply
X45
TNC keyboard
X46
Machine operating panel
X47
PLC expansion
X48
PLC analog input
X49
BF 120 flat panel (alternative to BC
120)
X31
NC power supply
X13, X30 Do not use
X65 not
installed
B
Signal ground
Protective ground (YL/GN)
Interfaces X1, X2, X3, X4, X6, X8, X12, X21, X22, X23, X41, X42, X43, X45, X46, X47, X49
comply with the recommendations in VDE 0160, 5. 88 for separation from line power.
Danger to internal components!
Do not engage or disengage any connections while the unit is under power.
The outputs at connection X.... (indicate pin number if appropriate) are metallically isolated
from the device electronics by means of optocouplers.