External device setup manual – IDEC High Performance Series User Manual

Page 130

Advertising
background image

Chapter 2

112

External Device Setup Manual

2.5.10

MELSEC-FX2N (CPU)

Bit Device

Device Name

Device Symbol

Address Range

Read
/Write

Address
Gradual

MICRO/I

PLC

Input Relay

X

X

0 - 337

R

*1

*1. Set this device using octal.

Output Relay

Y

Y

0 - 337

R/W

*1

Internal Relay

M

M

0 - 3071

R/W

Timer (contact)

TS

T

0 - 255

R

Counter (contact)

CS

C

0 - 255

R

Special Int. Relay

SM

SM

8000 - 8255

R

State

S

S

0 - 999

R/W

Word Device

Device Name

Device Symbol

Address Range

Read
/Write

Address
Gradual

MICRO/I

PLC

Input Relay

WX

X

0 - 360

R

*1

*2

*1. Set this device using octal.
*2. Set this device using a multiplier of 16.

Output Relay

WY

Y

0 - 360

R/W

*1

*2

Internal Relay

WM

M

0 - 3056

R/W

*2

Timer (current value)

TN

T

0 - 255

R

Counter (current value)

CN

C

0 - 199

R

32-Bit Counter (current value)

DCN

C

2000 - 2551

R

*3

*3. This device is a 32-bit device.

Data Register

D

D

0 - 7999

R/W

State

WS

S

0 - 976

R/W

*2

Special Int. Relay

WSM

SM

8000 - 8240

R

Special Register

SD

SD

8000 - 8255

R

Advertising
This manual is related to the following products: