72

External Device Setup Manual

2.3.2

Connection Diagram 2: Computer Link Unit (RS485) to MICRO/I

When using the QJ71C24 Serial Communication Unit, connect a terminator resistor in accordance with the instruction man-
ual.

Screw down terminal block

D-sub, 9P connector plug type

Screw down terminal block

Terminal

- When using the QJ71C24 Serial Communication Unit, connect a terminator resistor in accordance with the instruction

manual.

- There is no pin number corresponding to TERM on the HG2G-S/-5S/-5F, HG3G/4G. When inserting a termination resis-

tor, use a communication switch. For the setting of the switch, refer to Chapter 1 "3 Important Points Regarding Wiring"
on page 19
.