4.7.6

Restrictions

Maximum number of characters for a tag name is 256 characters.

Array elements can be up to 3 dimensions.

The maximum array number is 65535.

Up to 65535 tags can be used per Station No. in device settings.

When tags that contain 32-bit data are specified in WindO/I-NV2, the lower 16 bits are selected. The upper 16 bits
cannot be specified directly.

The external device cannot be monitored using the MICRO/I device monitor or MICRO/I-NV2.

WindO/I-NV2 supports RSLogix 5000 version 13 or later.

O/I-Link cannot be used when using an Ethernet/IP(Logix Native Tag) connection.

Does not support Predefined structures and Module-Defined structures except for the TIMER, COUNTER,CONTROL
structure.

Does not support the Strings data type.

Does not support the Alias.