External Device Setup Manual

When you use the Terminal Block type of HG1F, make sure to configure the Hardware Flow control to NONE.

Screw down terminal block

D-sub, 9P connector socket type

Screw down terminal block

Terminal

- When using the QJ71C24 Serial Communication Unit, connect a terminator resistor in accordance with the instruction

manual.

- There is no pin number corresponding to TERM on the HG1F. When inserting a termination resistor, use a communica-

tion switch. For the setting of the switch, refer to Chapter 1 "3 Important Points Regarding Wiring" on page 19.