Chapter 6

642

External Device Setup Manual

5

Restrictions

Note the following restrictions when performing 1: N communication.

Maximum number of units to be connected

Using RS485 : 31 units

Using Ethernet : 16 units

(May vary depending on the PLC type. Refer to the manual of your PLC for details.)

Maximum number of source devices at one time

The maximum number of devices (including O/I Link) that can be read at one time is 8192. Devices exceeding this limit cannot be read out.

Precautions for using the Simulation Mode

When the communication setting on the HG1F/2F/2S/3F/4F is set to 1:1, the external device values are retained even after
the screen is changed. However, if set to 1:N, or when using the HG2G-S/-5S/-5F, HG3G/4G, Touch, the external device
values are not retained.