4 environment settings, Environment settings, External device setup manual – IDEC High Performance Series User Manual

Page 273

Advertising
background image

255

6 Keyence

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

Con

nection

to a PLC

External Device Setup Manual

6.4

Environment Settings

6.4.1

KV-700/1000, Conventional KV series, Visual KV series

6.4.2

KV-1000/3000

Item

Setting

Interface

RS232C

Data Bits

8

Baud Rate (bps)

9600

Parity

Even

Stop Bits

1

-

Communication parameters are fixed. Please select above-mentioned settings for proper communication.

-

Refer to the PLC manual for details.

-

When you communicate with the CPU unit for KV-700, check the “Connect CPU Unit (Enable)/ Link Unit (Disable)” check box for the
communication setting.

Item

Setting

Interface

RS232C

Data Bits

8

Baud Rate (bps)

9600, 19200, 38400, 57600 or 115200

Parity

Even

Stop Bits

1

-

See the operation manual of PLC for more information.

-

When setting the baud rate to less than 4800 bps, communications was executed at a baud rate of 9600 bps.

-

When you communicate with the CPU unit for KV-1000/3000, check the “Connect CPU Unit (Enable)/ Link Unit (Disable)” check box for
the communication setting.

Advertising
This manual is related to the following products: