External Device Setup Manual

3.4.2

CPU Unit RS232C Link I/F Settings

Write the RS232C I/F setting item for the System Settings Area using a peripheral tool (such as Proconn).

Refer to the PLC manual for details.

For CQM 1 and C200HS, set the switch number 5 on the CPU Unit setting switch to OFF.

System Settings Area

Item

Setting

C20H/
28H/40H/60H

CQM1H
C200HS/
C200HE/
C200HG/
C200HX

DM0920

DM6645

Standard/Individual Setting

*1

*1. Standard settings

Baud Rate: 9600 bps
Data Bits: 7 bits
Stop Bits: 2 bits
Parity: Even

Same setting as the MICRO/I

Mode

PLC Link Mode

DM0921

DM6646

Communication parameters for when the
previous item is set to Individual.

Use the same settings as for the MICRO/I.

DM0922

DM6647

Transmission Delay

0 msec

RS/CS presence

None

DM0923

DM6648

Unit No.

Same setting as the MICRO/I