Vivotek MD9584-HF3 5MP Outdoor Network Mobile Dome Camera with Night Vision, Heater & 3.6mm Lens User Manual

Page 414

Advertising
background image

VIVOTEK

414 - User's Manual

© 2022 VIVOTEK INC. All Right Reserved

284

PARAMETER VALUE

DESCRIPTION

function

zoom,
focus,
auto,
scan,
stop,
positioning,
irisopen,
irisenable

zoom

- Move focus motor

focus

– Move focus motor

auto

– Perform auto focus

scan

– Perform focus scan

stop

– Stop current operation

positioning

– Position the motors

irisopen

– Fully open iris. It will maintain fully open iris

status until sending function=irisenable cgi.

irisenable

– return back to user setting status of iris.

direction

direct,
forward,
backward

Motor’s moving direction.
It works only if function=zoom or function=focus.

position

<motor_start> ~
<motor_end>

Motor’s position.
It works only if function=zoom or function= focus and
direction=direct.
<motor_start> : remote_focus_zoom_motor_start or
remote_focus_focus_motor_start,
<motor_end> : remote_focus_zoom_motor_end or
remote_focus_focus_motor_end replied from
"function=getstatus"

steps

1 ~ 30

Motor’s moving steps.
It works only if function=zoom or function=focus and
direction=forward and direction=backward.
* Motor will stop when it reaches to <motor_start> or
<motor_end>.
* This parameter is for additional fine-tune, the value is
from 1 to 30.

iris

N/A

Open iris or not.
It works only if function=auto or function=scan.


Syntax:

(for query API)

http://<

servername

>/cgi-bin/admin/remotefocus.cgi?channel=<value>&[function=<value>]

Advertising