Konica Minolta bizhub C650 User Manual

Page 19

Advertising
background image

Fusing unit, Ozone filter replacement instructions

2

4.

Open the multi bypass tray, and open
the upper right door [1].

5.

Loosen the two screws of the fusing
unit [1].

6.

Hold the position [2] as shown in the
left and remove the fusing unit [1].

A00JF2C542DA

[1]

CAUTION

• Do not remove any screws other than

the specified ones.

[1]

[1]

A00JF2C057DA

CAUTION

• When removing the fusing unit, grip it

with both hands to avoid letting the
fusing unit fall down.

A00JF2C605DA

[2]

[1]

[2]

Advertising
This manual is related to the following products: