Fusing unit, Ozone filter replacement instructions
2
4.
Open the multi bypass tray, and open
the upper right door [1].
5.
Loosen the two screws of the fusing
unit [1].
6.
Hold the position [2] as shown in the
left and remove the fusing unit [1].
A00JF2C542DA
[1]
CAUTION
• Do not remove any screws other than
the specified ones.
[1]
[1]
A00JF2C057DA
CAUTION
• When removing the fusing unit, grip it
with both hands to avoid letting the
fusing unit fall down.
A00JF2C605DA
[2]
[1]
[2]