Fusing unit, Ozone filter replacement instructions

3

1.2

Reinstallation procedure

1.

Install the new fusing unit [1] into the
main body.

2.

After ensuring that the surfaces are
level, secure the fusing unit by tight-
ening the two mounting screws [1]
on the back side first, and then the
front side.

CAUTION

• Press both ends of the fusing unit

until it is securely fixed in position.

A00JF2C558DA

[1]

CAUTION

• When reinstalling the fusing unit, be

sure to press the fusing unit into the
machine until the surfaces of the A [1]
and B [2] are level with each other.

• To remove unevenness between the

surfaces of the A and B, turn the mis-
feed-clearing dial [3] while pushing the
fusing unit into the machine.

[2]

[3]

[1]

A00KF2C508DA

WARNING

• Securely tighten the screws.

Otherwise you may suffer an electric
shock.

[1]

[1]

A00JF2C057DA