Transfer belt unit, 1 removal procedure – Konica Minolta bizhub C650 User Manual
Page 25
Transfer belt unit, Transfer roller unit replacement instructions
1
Transfer belt unit, Transfer roller unit replacement
instructions
1.
Transfer belt unit
1.1
Removal procedure
1.
Turn OFF the sub power switch [1].
2.
Turn OFF the main power switch [1].
3.
Unplug the power cord from the wall
outlet.
WARNING
• Before replacing parts, be sure to turn off the main and sub power
switches and unplug the power cord from the power outlet.
CAUTION
• The temperature gets high in the vicinity of the fusing unit. You may get
burned when you come into contact with the area.
Before replacement operations, make sure that more than 20 minutes
have elapsed since the main and sub power switches were turned off.
• When replacing parts, be sure not to touch the surrounding sensors and
rollers.
A00JF2C540DA
[1]
CAUTION
• The temperature gets high in
the vicinity of the fusing unit.
You may get burned when you
come into contact with the
area.
Before replacement opera-
tions, make sure that more
than 20 minutes have elapsed
since the main and sub power
switches were turned off.
A00JF2C541DA
[1]