19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.23
L_ArithmetikPhi_5
This FB can combine two angle signals arithmetically.
• The arithmetic function is selected in
.
• All internal intermediate results and the value provided at the dnOut_p output are internally
limited to ±2147483647 (±2
31
- 1).
• Division is not remainder considered.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
dnIn1_p
DINT
Input signal 1
dnIn2_p
DINT
Input signal 2
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2147483647
Parameter
Possible settings
Info
Function selection
0 dnOut_p = dnIn1_p
1 dnOut_p = dnIn1_p + dnIn2_p
2 dnOut_p = dnIn1_p - dnIn2_p
3 dnOut_p = dnIn1_p * dnIn2_p
4 dnOut_p = dnIn1_p / dnIn2_p
/B$ULWKPHWLN3KLB
GQ,QBS
GQ2XWBS
GQ,QBS
r
& )XQFWLRQ