8technology applications – Lenze 8400 TopLine User Manual

Page 499

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

499

8

Technology applications

8.4

TA "Table positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

wPosProfileMode

WORD

Override of the positioning mode set in the profile data

• Via this input, an override of the positioning mode parameterised in

C01300/1...15

for the selected profile is possible.

• The value set in

C01300/1...15

is not overwritten in this case.

• Only bit 0 ... bit 3 of wPosMode are evaluated.

• If wPosMode = 0 is selected, the positioning mode set in

C01300/1...15

is used.

0 Positioning mode = setting in

C01300/1...15

1 Absolute (shortest path)
2 Continuous
3 Relative
4 absolute (Cw)
5 absolute (Ccw)
8 Absolute (shortest path) to TP
9 Continuous to TP

10 Relative to TP
11 Absolute (Cw) on TP
12 Absolute (Ccw) on TP

All other possible settings are reserved for future extensions!

wPosProfileNo

WORD

Stipulation of the profile to be executed

• Optionally as a data word or binary coded.

bPosProfileNo_1

...

bPosProfileNo_8

BOOL

dnPosProfilePosition_p

DINT

Selection of the target position in [increments]

• The mode for calculating the position is selected in

C01296/1

.

wPosProfileUnitsLW

wPosProfileUnitsHW

WORD

Selection of the target position in [units]

wPosProfileUnitsLW = Low word, wPosProfileUnitsHW = High word

• The mode for calculating the position is selected in

C01296/1

.

GP: GeneralPurpose

The following inputs are interconnected with logic/arithmetic functions on application level for free usage.

"GeneralPurpose" functions

nGPAnalogSwitchIn1_a

nGPAnalogSwitchIn2_a

INT

Analog switch

: Input signals

• The input signal selected via the selection input bGPAnalogSwitchSet is output at

output nGPAnalogSwitchOut_a.

bGPAnalogSwitchSet

BOOL

Analog switch

: Selection input

FALSE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn1_a

TRUE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn2_a

nGPArithmetikIn1_a

nGPArithmetikIn2_a

INT

Arithmetic

: Input signals

• The arithmetic function is selected in

C00338

.

• The result is output at output nGPArithmetikOut_a.

nGPMulDivIn_a

INT

Multiplication/Division

: Input signal

• The factor for the multiplication can be set in

C00699/1

(numerator) and

C00699/2

(denominator).

• The result is output at output nGPMulDivOut_a.

bGPDigitalDelayIn

BOOL

Binary delay element

: Input signal

• The on-delay can be set in

C00720/1

.

• The off-delay can be set in

C00720/2

.

• The time-delayed input signal is output at output bGPDigitalDelayOut.

Identifier

Data type

Information/possible settings

Advertising