5motor control (mctrl) – Lenze 8400 TopLine User Manual
Page 313
Advertising
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
313
5
Motor control (MCTRL)
5.15
Internal status signals | System block "LS_DeviceMonitor"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
bWirebreakUfLinearActive
BOOL
(from version 15.00.00)
Status "V/f emergency operation due to encoder open circuit active"
• The internal change-over to "V/f emergency operation" can be suppressed by
setting bit 8 to "1" in
TRUE Due to an encoder open circuit, it is internally switched to the
encoderless V/f characteristic control in order to avoid impermissible
motor movements. This does not influence the setting in
Identifier
Data type
Value/meaning
Advertising