6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 363

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

363

6

Encoder/feedback system

6.5

Pole position identification (PPI)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to execute the pole position identification:

1. Inhibit the controller if it is enabled, e.g. via the

C00002/16

device command or a LOW

signal at the X5/RFR terminal.

2. Start the pole position identification with the device command

C00002/34

= "1: On / start".

3. Enable the controller again.

• The pole position identification starts.
• The progress of the identification run can be seen in

C00002/34

.

• The identification is completed if the "0: Off / ready" message is displayed in

C00002/34

.

4. Inhibit controller again.

After successful completion...
...the controller is inhibited automatically and the pole position determined for the activated

feedback system is set in the corresponding subcode of

C00926

.

• For a permanent acceptance of the identified pole position, the parameter set must be saved

(

C00002/11

= "1: On / start").

• The next controller inhibit and subsequent controller enable serve to cancel the controller

inhibit automatically set by the procedure (e.g. by first executing the device command

C00002/16

= "0: Off / ready" and then executing the device command

C00002/16

= "1: On /

start").

In the event of a fault
If an error occurs during the procedure or the pulse inhibit gets active (e.g. due to short-time

undervoltage), the procedure is terminated with controller inhibit without making a change in

C00926

.

If the machine was braked or blocked during the procedure, this will be recognised at the end of the

measurement and no change is made in

C00926

.

• If the pole position identification is aborted:

• the response parameterised in

C00643/1

(Lenze setting: "Fault") is activated.

• the error message "

Id5: Pole position identification error

" is entered into the logbook.

Advertising