6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 354

Advertising
background image

6

Encoder/feedback system

6.4

Frequency HTL encoder (DI1/DI2, DI6/DI7)

354

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

General procedure
(if the encoder is connected to the digital inputs DI1 and DI2)

1. Define the function of the digital inputs DI1 and DI2 in

C00115/1

.

2. Set the encoder increments in

C00420/1

.

3. Select "1: Encoder signal FreqIn12" in

C00495/1

.

4. Adapt the filter time of the speed measurement in

C00497/1

.

5. In the case of encoders with a very low resolution (number of increments < 120 increments):

Change the encoder evaluation procedure in

C00496

if necessary.