17 parameter reference – Lenze 8400 TopLine User Manual

Page 881

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

881

17

Parameter reference

17.2

Parameter list

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00002/23

0: Off / ready

Motor parameter identification

• This device command serves to carry out automatic

motor parameter identification.

• The identification method can be selected in

C02867

.

• The device command is only executed when the drive

controller is in the "SwitchedOn" status.

• In order to identify the motor parameters, the

controller must be enabled after this device

command.

Automatic motor parameter identification

C00002/24

0: Off / ready

Setting Hiperface position

From version 14.00.00

SinCos absolute value encoder with HIPERFACE®

protocol

C00002/25

0: Off / ready

Identify resolver error

• The device command is only executed when the drive

controller is in the "SwitchedOn" status.

e

Optimise resolver behaviour

C00002/26

0: Off / ready

CAN reset node

• Reinitialise "CAN on board" interface.

• Required when changing the baud rate, node address,

or identifiers.

"CAN on board" system bus

C00002/27

0: Off / ready

Device search function

• This device command serves to optically locate a

controller connected online (e.g. for maintenance

work).

Device search function

C00002/28

0: Off / ready

Check MasterPin

Unlocking the controller with a MasterPin

C00002/29

0: Off / ready

Set binding ID

Device personalisation

C00002/30

0: Off / ready

Delete binding ID

Device personalisation

C00002/31

0: Off / ready

Set password

Password protection

C00002/32

0: Off / ready

Check password

Password protection

C00002/33

0: Off / ready

Delete password

Password protection

C00002/34

0: Off / ready

Pole position identification (360°)

• This device command is serves to carry out an

automatic identification of the pole position.

• The device command is only executed when the drive

controller is in the "SwitchedOn" status.

• In order to identify the pole position, the controller

must be enabled after this device command.

Pole position identification

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Advertising