19 function library – Lenze 8400 TopLine User Manual

Page 1433

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1433

19

Function library

19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter

bNegOverrange

BOOL

Monitoring of lower home position

TRUE Lower home position (

C01463/2

) reached.

nVAdditive_a

INT

Material speed caused by the dancer motion

• Scaling: 16384 ≡ Maximum material speed (wVMax)

nVOut_a

INT

Current circumferential speed of the reel when the dancer hub is entered

• Scaling: 16384 ≡ Maximum material speed (wVMax)

nMAdditive_a

INT

Additional torque for damping the dancer position control

• Scaling: 16384 ≡ 100 %

Parameter

Possible settings

Info

C01460/1

0

ms

1000 TConst

• Time constant for filtering the

actual position value.

• Lenze setting: 10 ms

C01461/1

%

Upper limit position

• Lenze setting: 100.00 %

C01461/2

%

Lower limit position

• Lenze setting: -100.00 %

C01462/1

mm

dwLength

• Storage volumen of the dancer

(dancer hub).

• Lenze setting:

C01463/1

%

Upper home position

• Lenze setting: 90.00 %

C01463/2

%

Lower home position

• Lenze setting: -90.00 %

C01464/1

%

nWindowSetPos

• Tolerance zone for monitoring the

dancer position.

• Lenze setting: 10.00 %

C01465/1

s

wDelayTime

• Delay time for monitoring the

dancer position.

• Lenze setting: 0.100 s

C01466/1

ms

wTConstVAdd

• Time constant for filtering the

additional speed.

• Lenze setting: 10 ms

C01467/1

%

nDeadBand

• Dead band area for feedforward

control torque (nMAdditive_a).

• Lenze setting: 1.00 %

C01468/1

wDamping

• Damping factor for feedforward

control torque (nMAdditive_a).

• Lenze setting: 0.00

Identifier

Data type

Value/meaning