40 uart control – Vivotek FE9380-HV 5MP Outdoor Network Fisheye Dome Camera with Night Vision User Manual

Page 305

Advertising
background image

VIVOTEK

User's Manual - 305

zoomenhance

<boolean>

1/4 Enable / Disable zoom enhancement

tour_index

-1, 0~19

1/4

Index of the enabled tour group, from 0
to 19.
Set -1 to disable all the tour groups.

tour_i<0~19>_name

string[40]

1/4

Name of the tour.

tour_i<0~19>_type

<boolean>

1/4

0 = Recorded tour
1 = Preset tour

tour_i<0~19>_speed

-5 ~ 5

1/4

Preset tour: pan and tilt speed when
moving between presets.
Recorded tour: unnecessary.

tour_i<0~19>_checklist string[512]

1/4

The indexes of preset positions,
separated by “,”

tour_i<0~19>_dwelltime

string[512]

1/4

Preset tour: time to wait before moving
to the next preset position, separated by
“,”
Recorded tour: number of seconds to
wait
before continuing a loop tour.

7.40 UART control

Group:

uart

(capability.nuart > 0 and capability.fisheye = 0)

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

ptzdrivers_i<0~19,
127>_name

string[40]

1/4

Name of the PTZ driver.

ptzdrivers_i<0~19,
127>_location

string[128]

1/4

Full path of the PTZ driver.

enablehttptunnel

<boolean>

1/4

Enable HTTP tunnel channel to control UART.

Group:

uart_i<0~(n-1)>

n is uart port count (capability.nuart > 0 and capability.fisheye = 0)

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

baudrate 110,300,600,1200,

2400,3600,4800,72
00,9600,19200,384
00,57600,115200

4/4

Set baud rate of COM port.

databit

5,6,7,8

4/4

Data bits in a character frame.

Advertising