Settings and operations, Signal and sequencer operations, Connecting to external equipment – Pioneer Toraiz SQUID - Creative Multitrack Sequencer User Manual

Page 162

Advertising
background image

Connecting to external equipment

162

En

Settings and operations

Set the

[OUT1 Sync Mode]

or

[OUT2 Sync Mode]

of

[DIN SYNC]

setting in the GLOBAL menu to

[Sync24]

or

[Sync48]

according to

the timing clock rate of the device connected to each of the terminals.

When connecting the DIN SYNC OUT terminal of the connected
device to the

[DIN SYNC IN/OUT2]

terminal set to

[IN]

to use this unit

as the slave device, set

[Sync Source]

of the

[Sync Common]

setting in the GLOBAL menu to

[DIN SYNC]

and set

[OUT2 Sync

Mode]

of

[DIN SYNC]

setting correctly according to the timing clock

rate of the connected device.

The operations by Reset Start and Continue Start operations may
differ depending on the connected device. Check the manual of the
connected device and set

[OUT1 Cont/Rst Start]

or

[OUT2 Cont/

Rst Start]

of the

[DIN SYNC]

setting correctly in accordance with the

Reset Start and Continue Start operations of the unit.

When connecting to a device that does not support the Reset Start
and Continue Start specifications of the unit, set it to avoid
malfunctions on the unit or the connected device caused by external
noise.

Signal and sequencer operations

This unit synchronizes with the timing when the Start/Stop signals
instruct the sequence performance, and sends Continue Start or Reset
Start signal from the

[DIN SYNC OUT1]

terminal or

[DIN SYNC IN/

OUT2]

terminal set to

[OUT]

at the timing shown below.

If the Continue Start or Reset Start signal is received at the

[DIN SYNC

IN/OUT2]

terminal set to

[IN]

at the timing shown below, the sequencer

operation is restarted from the stop position or played from the first
step.

Advertising