Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 10

Advertising
background image

2-2

This equipment is manufactured to use the type of gas specified on the rating plate attached to the
door. Connect equipment stamped “NAT” only to natural gas and that stamped “PRO” only to LP
(Propane) gas.

Installation shall be made with a gas connector that complies with national and local codes. Quick
disconnect devices, if used, shall likewise comply with national and local codes.

ELECTRICAL GROUNDING REQUIREMENTS

All electrically operated appliances must be grounded in accordance with all applicable national and
local codes. A wiring diagram is located on the inside of the door. In the United States and Canada,
the electrical supply must be 120VAC, 60 Hz. In other countries, refer to the rating plate on the in-
side of the door for proper voltages.

FCC COMPLIANCE

The user is cautioned that any changes or modifications to Frymaster computers not expressly ap-
proved by the party responsible for compliance could void the user’s authority to operate the equip-
ment. Frymaster computers have been tested and found to comply with the limits for a Class A digi-
tal device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices,
they have been shown to meet the Class B limits. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio com-
munications. Operation of the equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense. If necessary,
the user should consult the dealer or an experienced radio and television technician for additional
suggestions.

The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” help-
ful. It is prepared by the Federal Communications Commission and is available from the U.S. Gov-
ernment Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.

2.2 Caster/Leg

Installation

Your unit requires casters or legs to be installed. IT MAY NOT BE CURB MOUNTED!

If casters or legs are not already installed, install them in accordance the instructions included
in your accessory package. FAILURE TO INSTALL CASTERS OR LEGS WILL RESULT
IN IMPROPER OPERATION OF YOUR UNIT.



2.3 Pre-Connection

Preparations

DANGER

Do not connect this equipment to the gas supply before completing each step in this
section.

Advertising
This manual is related to the following products: