FBR18 & FBRA18 SERIES GAS RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1 Introduction

Mechanically, the FBR18 and FBRA18 rethermalizers are virtually identical, the only difference
being that the FBRA18 units have an automatic filling (AutoFill) feature. Both units use the same
digital temperature controller and mechanical timers.

In operation, a setpoint is programmed into the controller which then regulates burner firing to
maintain the water in the cookpot at the desired temperature. Six individual color-coded mechani-
cal timers allow different types or quantities of product to be rethermalized simultaneously. The
timers are equipped with an alarm to notify the operator that rethermalizing is complete. The prod-
uct baskets have color-coded handles that correspond to the timers to eliminate confusion.

3.2

FBR18/FBRA18 Digital Controller

Heating

Mode

Indicator

Setpoint

Adjustment

Arrows

Temperature

or Setpoint

Display Switch

Melt

Cycle

Switch

Digital

Display

Power

Switch

Celsius or

Fahrenheit

Display Switch

Frymaster

9 . 9 9 9

C

O

PERATING THE

FBR18/FBRA18

D

IGITAL

C

ONTROLLER

WARNING

Ensure the cookpot is filled with water before turning the controller on. “Dry firing”
will cause damage to the cookpot!


1. Turn the controller on by pressing the Power

switch. The controller software version num-

ber will display for 4 seconds in the digital display then change to the last programmed setpoint