Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 45

Advertising
background image

6-18

6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued)

NOTE: All voltage measurements involving the

gas valve leg of the 24V circuit must be made

within 4 seconds of unit calling for heat. If unit

does not fire within 4 seconds, ignition

modules will lock out and controller must be

turned off then back on to reset.

B

Is 24VAC

present across the gas

valve main coil (PV)

terminal?

Gas valve leg

of 24V circuit is

OK.

Is

24VAC present on

VALVE terminal of LEFT

ignition module?

Probable cause is

failed wiring between

module and gas valve.

Is 24VAC present

on 25V terminal of LEFT

ignition module?

If fuse is not

blown, module

has failed.

Is 24VAC

present on J2

pin 4?

Is 24VAC present

on 25V terminal of RIGHT

ignition module?

Is

24VAC present on

VALVE terminal of RIGHT

ignition module?

Probable cause

is failed wiring

harness.

Probable causes are failed

wiring between blower centrifugal

switch and module, failed

centrifugal switch, or failed

wiring harness.

Is 24VAC

present on J2

pin 3?

Probable cause
is failed CYCLE

relay.

Probable cause is

failed wiring between

terminal block and J2

pin 3.

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

No

Yes

Yes

No