Controller and mechanical timers, Interface boards – Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 29

Advertising
background image

6-2

guished), current to the ignition module is cut, preventing the main valve from opening, and the igni-
tion module “locks out” until the power switch is turned off and then back on.
A probe monitors the temperature in the cookpot. When the programmed setpoint temperature is
reached, resistance in the probe causes the heat cycle circuitry in the controller to cut off current
flow through the heat relay. This in turn cuts off the 24 VAC to the ignition module, causing the gas
valve to close.

CONTROLLER AND MECHANICAL TIMERS


FBR18 and FBRA18 Series rethermalizers are equipped with a digital controller that allows the op-
erator to enter or adjust a specific rethermalizing temperature for the cookpot. The controller does
not control rethermalizing times. Rethermalizing times for up to six different products are specified
by means of 60-minute mechanical timers arrayed across the front of the unit.


INTERFACE BOARDS

An interface board is located in the component box directly behind the control panel. The interface
board provides a link between the controller and the rethermalizer’s individual components without
requiring excessive wiring, and it allows the controller to execute commands from one central point.
FBR18 and FBRA18 models use different interface boards. The boards are not interchangeable.

FBR18 rethermalizers have been manufactured with two different interface boards, similar in ap-
pearance to the ones illustrated below. Regardless of the board used when manufactured, the uni-
versal replacement part is 806-3398.
Earlier design boards may be replaced with later design
boards and vice versa.

K4

K1

K2

SOUND

1

2

3

GND

GND

V2D

PWR

AD

AS

V2S

GND

V1D

PWR

ALR

V1S

GND

GV PWR AL 12V AIR 24V AL PWR GV

GND

NOT

USED

HEAT

RELAY

J2

EARLIER DESIGN INTERFACE BOARD P/N 806-3398

GND

1

2

6

3

4

5

J3

3

6

9

12

2

5

8

11

1

4

7

10

J1

3

6

9

12

2

5

8

11

1

4

7

10

15

12

9

6

3

14

11

8

5

2

13

10

7

4

1

BLOWER

MOTOR

RELAY

NOT

USED

NOT

USED

K3

K5

K4

K1

SOUND

1

2

3

GND

GND

V2D

PWR

AD

AS

V2S

GND

GV

PWR

12V

AIR

24V

PWR

GND

V1D

PWR

ALR

V1S

GV

GND

J2

LATER DESIGN INTERFACE BOARD P/N 806-3398

GND

J3

3

6

9

12

2

5

8

11

1

4

7

10

J1

3

6

9

12

2

5

8

11

1

4

7

10

15

12

9

6

3

14

11

8

5

2

13

10

7

4

1

K2

K3

HEAT

RELAY

AND

BLOWER

MOTOR

RELAY

NOT

USED

D1

D2

D3

D4

D6

D7

NOT

USED

NOT

USED

Blower

Motor

2 Amp

D5

In earlier versions, nine diagnostic LEDs are arrayed along the bottom edge of the board. Each of
the LEDs is labeled with two or three letters indicating its function, and six of them are numbered.
In later versions, there are seven LEDs scattered around the board. All of these LEDs are labeled
and numbered. The diagnostic purposes of LEDs 1 through 6 on one board correspond directly to
those of LEDs 1 through 6 on the other board.
When lit, LED 3 indicates the 24VAC is being re-
ceived from the transformer. LEDs 2 and 4, when lit, indicate that 24VAC is being supplied to the
left and right ignition modules respectively. LED 5, when lit, indicates that 24VAC is being sup-
plied to the gas valve. A lit LED 6 indicates that 12VAC is being received from the transformer.
All other LEDs have no diagnostic purpose in rethermalizer applications.