5-3

WATER DID NOT SHUT

OFF WHEN COOKPOT

WAS FULL.

Use bottlebrush to clean

water level sensors.

Did water

stop?

Problem

resolved.

Add 1/8 cup of salt to

water in cookpot and

stir.

Did water

stop?

Mineral content of water is

insufficient for water sensor to

detect it. Whenever cookpot is

refilled, add 1/8 cup of salt.

Open control panel by

removing screws in each

upper corner.

Is WATER

LED on interface board

illuminated?

Remove the cover over the

water sensors and thoroughly

clean the sensors with a

Scotchbrite or similar pad.

If water still does not stop,

probable cause is

failed/loose high water

sensor wiring.

Call FASC.

Probable cause is failed

water solenoid.