Frymaster Gas Rethermalizers FBRA18 Series User Manual

Page 15

Advertising
background image

3-2

NOTE: The unit comes from the factory configured to display in degrees Fahrenheit. To toggle
back and forth between Fahrenheit and Celsius, press the Celsius/Fahrenheit display

switch.

2. The controller will automatically cycle the burners on and off seven times or until the tempera-

ture in the cookpot reaches 160

°F (71°C), whichever comes first. At that time, it will enter the

continuous heat mode. When in the continuous heat mode the Heat Mode indicator (a decimal
point between the first two digits of the temperature display) will appear. When the setpoint is
reached, the Heat Mode indicator will go out, indicating the rethermalizer is ready for use.


3. To enter or change the setpoint temperature, press the up

arrow key to raise the setpoint or

the down

arrow keys to lower the setpoint. The display will change at a rate of about 1

degree per second for approximately the first 12 degrees, then change at a faster rate if the
arrow is continuously pressed.


4. Pressing the Temperature/Setpoint display

switch toggles the display back and forth be-

tween constant temperature display and constant setpoint display. Use this feature if you want
to check the actual cookpot temperature.


5. To turn the controller (and burners) off, press the Power

switch.

O

PERATING THE

FBR18/FBRA18

T

IMERS


1. Place a packet of product in one of the rethermalizing baskets and note the handle color of the

basket.


2. Place the basket into the water and rotate the correspondingly colored timer knob to the desired

rethermalizing time, up to 60 minutes.


3. An alarm will sound when the rethermalizing time has elapsed.

3.3 Start-Up

Procedure

CAUTION

If this is the first time the unit is being used after installation, refer to Section 3.4,
Boiling-Out the Cookpot.


Before turning the rethermalizer on, ensure that:

the unit is connected to the water supply

the water supply is turned on

the unit is plugged into a 120VAC outlet

the electrical power supply to the rethermalizer is turned on

the gas supply to the rethermalizer is turned on.

Advertising
This manual is related to the following products: